| Action | When | Mission | Type | Asset | Waypoint | Battery | Duration | Result | Reading | Anomaly |
|---|---|---|---|---|---|---|---|---|---|---|
| A0008 | 2026-09-01 18:24 | M001 V1 | Thermal | PANEL-218 Electrical Panel 18 | WP07 Control Room Corridor | 28% | 47 s | Success | 72.9 C | — |
| A0022 | 2026-09-02 10:05 | M003 V1 | Thermal | COMP-214 Compressor 14 | WP04 Pump Bay | 63% | 79 s | Success | 65.3 C | — |
| A0023 | 2026-09-02 10:08 | M003 V1 | Thermal | PUMP-205 Pump 05 | WP10 Valve Station | 58% | 88 s | Success | — | — |
| A0025 | 2026-09-02 10:14 | M003 V1 | Thermal | PUMP-205 Pump 05 | WP10 Valve Station | 46% | 23 s | Success | 75.1 C | — |
| A0028 | 2026-09-02 10:22 | M003 V1 | Thermal | HX-201 Heat Exchanger 01 | WP15 Inspection Dock | 29% | 23 s | Failed Target not detected | 59.1 C (questionable) | Abnormal temperature MEDIUM |
| A0029 | 2026-09-02 10:25 | M003 V1 | Thermal | HX-204 Heat Exchanger 04 | WP05 Pipe Gallery | 23% | 51 s | Failed Target not detected | 51.7 C (questionable) | Abnormal temperature LOW |
| A0033 | 2026-09-02 18:09 | M004 V1 | Thermal | HX-213 Heat Exchanger 13 | WP07 Control Room Corridor | 65% | 36 s | Success | 70.6 C | — |
| A0036 | 2026-09-02 18:18 | M004 V1 | Thermal | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 49% | 41 s | Success | 74.9 C | — |
| A0042 | 2026-09-03 02:05 | M005 V1 | Thermal | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 66% | 66 s | Success | 64.6 C | — |
| A0050 | 2026-09-03 02:25 | M005 V1 | Thermal | HX-208 Heat Exchanger 08 | WP03 Cooling Loop | 20% | 13 s | Success | 60 C | — |
| A0059 | 2026-09-03 10:27 | M006 V1 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 21% | 79 s | Success | — | — |
| A0066 | 2026-09-03 18:16 | M007 V1 | Thermal | HX-219 Heat Exchanger 19 | WP07 Control Room Corridor | 47% | 80 s | Success | — | — |
| A0067 | 2026-09-03 18:18 | M007 V1 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 41% | 23 s | Success | 65.6 C | — |
| A0079 | 2026-09-04 02:23 | M008 V1 | Thermal | PUMP-205 Pump 05 | WP02 Electrical Room | 18% | 67 s | Failed Reading unreliable | 71.3 C (questionable) | — |
| A0084 | 2026-09-04 10:10 | M009 V1 | Thermal | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 51% | 12 s | Success | 67.4 C | — |
| A0095 | 2026-09-04 18:16 | M010 V1 | Thermal | PANEL-212 Electrical Panel 12 | WP09 Turbine Hall South | 45% | 76 s | Success | 63 C | — |
| A0098 | 2026-09-04 18:26 | M010 V1 | Thermal | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 26% | 30 s | Success | 53.9 C | — |
| A0107 | 2026-09-05 02:23 | M011 V1 | Thermal | COMP-214 Compressor 14 | WP04 Pump Bay | 37% | 71 s | Success | 52.5 C | — |
| A0114 | 2026-09-05 10:10 | M012 V1 | Thermal | HX-216 Heat Exchanger 16 | WP13 Warehouse Corridor | 47% | 9 s | Success | — | — |
| A0117 | 2026-09-05 10:18 | M012 V1 | Thermal | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 30% | 14 s | Success | 53.6 C | — |
| A0118 | 2026-09-05 10:21 | M012 V1 | Thermal | PANEL-218 Electrical Panel 18 | WP15 Inspection Dock | 24% | 18 s | Failed Sensor timeout | 63 C (questionable) | Abnormal temperature MEDIUM |
| A0119 | 2026-09-05 10:24 | M012 V1 | Thermal | PANEL-215 Electrical Panel 15 | WP08 Turbine Hall North | 19% | 75 s | Failed Reading unreliable | 82.8 C (questionable) | Abnormal temperature MEDIUM |
| A0120 | 2026-09-05 10:27 | M012 V1 | Thermal | GAUGE-209 Pressure Gauge 09 | WP02 Electrical Room | 13% | 13 s | Failed Reading unreliable | — | Abnormal temperature LOW |
| A0127 | 2026-09-05 18:22 | M013 V1 | Thermal | HX-204 Heat Exchanger 04 | WP05 Pipe Gallery | 38% | 67 s | Failed Target not detected | 76.1 C (questionable) | — |
| A0128 | 2026-09-05 18:25 | M013 V1 | Thermal | VALVE-207 Valve 07 | WP12 Heat Exchanger Area | 33% | 48 s | Success | 65.1 C | — |
| A0149 | 2026-09-06 10:30 | M015 V1 | Thermal | HX-216 Heat Exchanger 16 | WP13 Warehouse Corridor | 32% | 29 s | Success | 39.8 C | — |
| A0154 | 2026-09-06 18:10 | M016 V1 | Thermal | HX-219 Heat Exchanger 19 | WP07 Control Room Corridor | 53% | 83 s | Success | 65.3 C | — |
| A0156 | 2026-09-06 18:15 | M016 V1 | Thermal | HX-202 Heat Exchanger 02 | WP05 Pipe Gallery | 42% | 11 s | Success | 75.5 C | — |
| A0164 | 2026-09-07 02:12 | M017 V1 | Thermal | PANEL-218 Electrical Panel 18 | WP12 Heat Exchanger Area | 53% | 60 s | Success | 68.2 C | — |
| A0170 | 2026-09-07 02:31 | M017 V1 | Thermal | PANEL-218 Electrical Panel 18 | WP12 Heat Exchanger Area | 16% | 30 s | Success | — | — |
| A0176 | 2026-09-07 10:19 | M018 V1 | Thermal | HX-217 Heat Exchanger 17 | WP15 Inspection Dock | 50% | 86 s | Success | 65 C | — |
| A0184 | 2026-09-07 18:08 | M019 V2 | Thermal | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 76% | 8 s | Success | 77.6 C | — |
| A0188 | 2026-09-07 18:17 | M019 V2 | Thermal | PANEL-203 Electrical Panel 03 | WP02 Electrical Room | 69% | 67 s | Success | — | — |
| A0193 | 2026-09-08 02:06 | M020 V2 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 81% | 39 s | Success | 43.8 C | — |
| A0194 | 2026-09-08 02:08 | M020 V2 | Thermal | HX-204 Heat Exchanger 04 | WP07 Control Room Corridor | 80% | 26 s | Success | 41.4 C | Abnormal temperature CRITICAL |
| A0195 | 2026-09-08 02:10 | M020 V2 | Thermal | PUMP-205 Pump 05 | WP10 Valve Station | 78% | 21 s | Success | 72.5 C | — |
| A0196 | 2026-09-08 02:12 | M020 V2 | Thermal | VALVE-207 Valve 07 | WP12 Heat Exchanger Area | 76% | 60 s | Success | 70.8 C | — |
| A0207 | 2026-09-08 10:15 | M021 V2 | Thermal | PUMP-205 Pump 05 | WP10 Valve Station | 75% | 57 s | Success | 64.7 C | — |
| A0214 | 2026-09-08 18:09 | M022 V2 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 79% | 61 s | Success | 48.3 C | — |
| A0218 | 2026-09-08 18:19 | M022 V2 | Thermal | HX-216 Heat Exchanger 16 | WP13 Warehouse Corridor | 72% | 64 s | Success | — | — |
| A0219 | 2026-09-08 18:21 | M022 V2 | Thermal | COMP-214 Compressor 14 | WP04 Pump Bay | 70% | 89 s | Success | 77.3 C | — |
| A0223 | 2026-09-09 02:06 | M023 V2 | Thermal | HX-213 Heat Exchanger 13 | WP13 Warehouse Corridor | 81% | 67 s | Success | 53.6 C | — |
| A0227 | 2026-09-09 02:14 | M023 V2 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 65% | 51 s | Success | — | — |
| A0228 | 2026-09-09 02:16 | M023 V2 | Thermal | HX-201 Heat Exchanger 01 | WP05 Pipe Gallery | 60% | 77 s | Success | 83.5 C | — |
| A0237 | 2026-09-09 10:13 | M024 V2 | Thermal | HX-216 Heat Exchanger 16 | WP02 Electrical Room | 66% | 14 s | Success | 62.5 C | — |
| A0238 | 2026-09-09 10:15 | M024 V2 | Thermal | PANEL-203 Electrical Panel 03 | WP15 Inspection Dock | 62% | 33 s | Success | 57.4 C | — |
| A0246 | 2026-09-09 18:10 | M025 V2 | Thermal | HX-210 Heat Exchanger 10 | WP11 Battery Room | 80% | 14 s | Success | 73.9 C | — |
| A0253 | 2026-09-10 02:06 | M026 V2 | Thermal | HX-216 Heat Exchanger 16 | WP13 Warehouse Corridor | 73% | 79 s | Success | 67.1 C | — |
| A0264 | 2026-09-10 10:10 | M027 V2 | Thermal | PANEL-211 Electrical Panel 11 | WP07 Control Room Corridor | 80% | 43 s | Success | 57.8 C | — |