| Action | When | Mission | Type | Asset | Waypoint | Battery | Duration | Result | Reading | Anomaly |
|---|---|---|---|---|---|---|---|---|---|---|
| A0003 | 2026-09-01 18:09 | M001 V1 | Acoustic | PUMP-205 Pump 05 | WP10 Valve Station | 62% | 16 s | Success | 63.5 dB | — |
| A0005 | 2026-09-01 18:15 | M001 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 48% | 69 s | Success | 71.9 dB | — |
| A0013 | 2026-09-02 02:09 | M002 V1 | Acoustic | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 64% | 31 s | Success | 85 dB | — |
| A0016 | 2026-09-02 02:18 | M002 V1 | Acoustic | PANEL-211 Electrical Panel 11 | WP09 Turbine Hall South | 48% | 79 s | Failed Reading unreliable | 66.6 dB (questionable) | Abnormal vibration MEDIUM |
| A0019 | 2026-09-02 02:27 | M002 V1 | Acoustic | HX-210 Heat Exchanger 10 | WP11 Battery Room | 33% | 16 s | Success | 71.7 dB | — |
| A0044 | 2026-09-03 02:10 | M005 V1 | Acoustic | COMP-214 Compressor 14 | WP04 Pump Bay | 55% | 8 s | Success | 79.7 dB | — |
| A0046 | 2026-09-03 02:15 | M005 V1 | Acoustic | PANEL-203 Electrical Panel 03 | WP05 Pipe Gallery | 43% | 20 s | Success | 81.9 dB | — |
| A0047 | 2026-09-03 02:17 | M005 V1 | Acoustic | HX-201 Heat Exchanger 01 | WP15 Inspection Dock | 37% | 82 s | Success | 80.2 dB | — |
| A0055 | 2026-09-03 10:15 | M006 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 44% | 8 s | Failed Sensor timeout | 67.7 dB (questionable) | Abnormal vibration MEDIUM |
| A0070 | 2026-09-03 18:27 | M007 V1 | Acoustic | PANEL-203 Electrical Panel 03 | WP05 Pipe Gallery | 25% | 10 s | Failed Sensor timeout | 70.5 dB (questionable) | Abnormal vibration LOW |
| A0072 | 2026-09-04 02:05 | M008 V1 | Acoustic | PANEL-218 Electrical Panel 18 | WP15 Inspection Dock | 62% | 90 s | Success | — | — |
| A0076 | 2026-09-04 02:15 | M008 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 37% | 49 s | Failed Reading unreliable | 77.5 dB (questionable) | Abnormal vibration MEDIUM |
| A0082 | 2026-09-04 10:05 | M009 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 60% | 37 s | Success | 70.7 dB | — |
| A0087 | 2026-09-04 10:17 | M009 V1 | Acoustic | HX-202 Heat Exchanger 02 | WP05 Pipe Gallery | 39% | 90 s | Success | 58.5 dB | — |
| A0089 | 2026-09-04 10:22 | M009 V1 | Acoustic | PANEL-212 Electrical Panel 12 | WP09 Turbine Hall South | 30% | 31 s | Failed Signal noise | 81.5 dB (questionable) | — |
| A0093 | 2026-09-04 18:09 | M010 V1 | Acoustic | COMP-214 Compressor 14 | WP04 Pump Bay | 57% | 73 s | Failed Reading unreliable | — | — |
| A0102 | 2026-09-05 02:06 | M011 V1 | Acoustic | HX-202 Heat Exchanger 02 | WP05 Pipe Gallery | 68% | 67 s | Success | 65.6 dB | — |
| A0110 | 2026-09-05 02:33 | M011 V1 | Acoustic | PANEL-218 Electrical Panel 18 | WP15 Inspection Dock | 18% | 35 s | Failed Reading unreliable | 70.9 dB (questionable) | — |
| A0115 | 2026-09-05 10:13 | M012 V1 | Acoustic | HX-217 Heat Exchanger 17 | WP08 Turbine Hall North | 41% | 53 s | Success | 71.1 dB | — |
| A0129 | 2026-09-05 18:28 | M013 V1 | Acoustic | HX-202 Heat Exchanger 02 | WP07 Control Room Corridor | 28% | 32 s | Success | 81.9 dB | — |
| A0130 | 2026-09-05 18:32 | M013 V1 | Acoustic | HX-213 Heat Exchanger 13 | WP13 Warehouse Corridor | 23% | 75 s | Success | 66.1 dB | — |
| A0135 | 2026-09-06 02:13 | M014 V1 | Acoustic | HX-213 Heat Exchanger 13 | WP13 Warehouse Corridor | 45% | 66 s | Success | 68.8 dB | — |
| A0140 | 2026-09-06 02:26 | M014 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP02 Electrical Room | 22% | 67 s | Success | 76 dB | — |
| A0145 | 2026-09-06 10:17 | M015 V1 | Acoustic | HX-208 Heat Exchanger 08 | WP03 Cooling Loop | 52% | 53 s | Success | 82.4 dB | — |
| A0146 | 2026-09-06 10:20 | M015 V1 | Acoustic | COMP-214 Compressor 14 | WP04 Pump Bay | 47% | 9 s | Failed Sensor timeout | 59.8 dB (questionable) | Abnormal vibration LOW |
| A0147 | 2026-09-06 10:23 | M015 V1 | Acoustic | HX-213 Heat Exchanger 13 | WP07 Control Room Corridor | 42% | 87 s | Failed Signal noise | — | Abnormal vibration HIGH |
| A0162 | 2026-09-07 02:06 | M017 V1 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 65% | 49 s | Success | — | — |
| A0173 | 2026-09-07 10:09 | M018 V1 | Acoustic | HX-213 Heat Exchanger 13 | WP08 Turbine Hall North | 66% | 86 s | Success | 65.9 dB | — |
| A0197 | 2026-09-08 02:14 | M020 V2 | Acoustic | PANEL-203 Electrical Panel 03 | WP15 Inspection Dock | 75% | 48 s | Success | 77.5 dB | — |
| A0199 | 2026-09-08 02:18 | M020 V2 | Acoustic | PANEL-211 Electrical Panel 11 | WP09 Turbine Hall South | 72% | 79 s | Success | — | — |
| A0200 | 2026-09-08 02:20 | M020 V2 | Acoustic | PUMP-205 Pump 05 | WP10 Valve Station | 70% | 41 s | Success | 64.8 dB | Abnormal vibration MEDIUM |
| A0203 | 2026-09-08 10:06 | M021 V2 | Acoustic | VALVE-207 Valve 07 | WP15 Inspection Dock | 88% | 48 s | Failed Reading unreliable | 52.9 dB (questionable) | — |
| A0205 | 2026-09-08 10:11 | M021 V2 | Acoustic | PUMP-205 Pump 05 | WP10 Valve Station | 82% | 55 s | Success | 69.4 dB | — |
| A0209 | 2026-09-08 10:19 | M021 V2 | Acoustic | HX-217 Heat Exchanger 17 | WP06 Compressor Area | 68% | 45 s | Success | 65.8 dB | — |
| A0217 | 2026-09-08 18:16 | M022 V2 | Acoustic | PANEL-215 Electrical Panel 15 | WP01 Main Entrance | 73% | 11 s | Success | 68.4 dB | — |
| A0229 | 2026-09-09 02:18 | M023 V2 | Acoustic | HX-208 Heat Exchanger 08 | WP02 Electrical Room | 56% | 25 s | Success | — | — |
| A0233 | 2026-09-09 10:05 | M024 V2 | Acoustic | PUMP-205 Pump 05 | WP10 Valve Station | 82% | 76 s | Failed Sensor timeout | 79.6 dB (questionable) | Abnormal vibration HIGH |
| A0240 | 2026-09-09 10:19 | M024 V2 | Acoustic | COMP-214 Compressor 14 | WP04 Pump Bay | 54% | 40 s | Success | 68.2 dB | — |
| A0247 | 2026-09-09 18:12 | M025 V2 | Acoustic | HX-210 Heat Exchanger 10 | WP11 Battery Room | 78% | 59 s | Failed Signal noise | 64.7 dB (questionable) | Abnormal vibration HIGH |
| A0255 | 2026-09-10 02:11 | M026 V2 | Acoustic | MOTOR-206 Motor 06 | WP14 Auxiliary Systems Bay | 67% | 81 s | Success | 68 dB | — |
| A0260 | 2026-09-10 02:23 | M026 V2 | Acoustic | HX-210 Heat Exchanger 10 | WP15 Inspection Dock | 52% | 66 s | Success | 79.4 dB | — |
| A0262 | 2026-09-10 10:05 | M027 V2 | Acoustic | VALVE-207 Valve 07 | WP12 Heat Exchanger Area | 86% | 67 s | Success | 70.5 dB | — |
| A0265 | 2026-09-10 10:12 | M027 V2 | Acoustic | HX-202 Heat Exchanger 02 | WP02 Electrical Room | 76% | 49 s | Failed Reading unreliable | 70.8 dB (questionable) | Abnormal vibration HIGH |